New Features

New Features

What's New Now

Quote
The following new and enhanced features are available in:
  1. Build 4.072

InfoFor instructions on how to upgrade, click here.

MediaSuite New Features Release - Build 4.090

The following feature is available in Build 4.090 and higher.

New Features

Native Second Opinion Viewer
Native Second Opinion Viewer is now integrated with MediaSuite and is an AI tool from Hello Pearl that allows users to view numerous conditions on dental x-rays within the MediaSuite interface.
Info
Here is more information (link coming soon).
To request a demo click here

Previous Updates

MediaSuite New Features Release - Build 4.072

The following fixes are available in Build 4.072 and higher.

Fixes

  1. MediaSuite Classic - CMSupport build 4.069.10 bug - Files Storage copy tool disappeared
  2. MediaSuite Online - crashing with "Unlock not locked slide" error in AU1513/AU26/AU1206/AU6634

MediaSuite New Features Release - Build 4.069

The following new and enhanced features are available in Build 4.069 and higher.

New and Enhanced Features 

Email Setup Settings
CMS Email Service OAuth2.0 support for SMTP. OAuth2 option for the Email setup. 

CMS Radiological Log Report
CMS Radiological Log. New Radiology log has been added to the CMS reports. 

MediaScan Corner Filter
CMS Corner mask filter for MediaScan

A new Corner Mask filter can be applied in the MediaScan capture window. The filter applies the mask around the Image plate and makes all the outer space black as illustrated below. 

CMS Default modality by Device 
The X-Ray/Other devices have the default DICOM modalities assigned to them automatically while in the capture window. TWAIN devices have OT DICOM modality assigned automatically. These can be changed. 

Import and View 3D Images
DICOM 3D volumes can now be imported and viewed in MediaSuite Classic. The images will be imported in the same format. 3D images can be viewed 1 slice at a time. Volumes can only be viewed, any changes made during a session will not be saved.

Export Imported 3D Volumes
3D Volumes that have been imported can be exported. 

Display System Information to include imported 3D images data
The updated Display System information interface has image data on imported 3D volume

CMScan interface has patient details
The patient details are now on top of the CMScan interface

New Fields added to Properties Diagnosis Window
DICOM Modality, kV, mA and ms fields added to Image properties/diagnosis window. These fields need to be either manually entered or may be automatically entered depending on what device is being used. 

Select Multiple Annotations
More than one annotation can be selected on an image by pressing the Alt key and selecting the annotations by the mouse clicks. These selected annotations can be deleted at once and their attributes can be updated at the same time. 

MediaSuite New Features Release - Build 4.043

The following changes are available in Build 4.043 and higher. 

New and Enhanced Features 

Database Engine Upgrade
The new Mediasuite build will be on ASA 17 database engine.  

MediaSuite New Features Release - Build 4.042

The following new and enhanced features are available in Build 4.042 and higher.

New and Enhanced Features 

DICOM Modality Worklist (MWL) SCU
The patient and study information can be imported into Mediasuite from the hospital information system using the DICOM Modality Worklist service.

DICOM Storage SCU
This feature allows sending images to a DICOM archive.
 

DICOM Automatic Store SCU
If the ‘Automatic DICOM store’ option is selected in the ‘DICOM configuration settings’ all images that are captured from a hardware device or are imported or pasted into Mediasuite, will be automatically sent to the DICOM store.

Images that are imported from a DICOM source or are imported after conversion will not be automatically sent to the DICOM server even if this option is on. 

InfoThis is an optional module, for more information contact your Sales representative - Click here

DICOM Storage Commitment SCU
This feature checks the status of the images which were previously sent to the server (PACS) by the DICOM Store.

DICOM Query/Retrieve SCU
The Query / Retrieve feature allows the search and retrieval of the patient, study, series, and image data from other DICOM workstations or DICOM archives (PACS) 

Mediascan interface - auto-connect in Network mode
Mediasuite automatically detects the status of the Mediascan scanner and immediately connects once the scan by another PC is finished and the device becomes available for connection. Don’t need to reopen Mediascan interface in the Mediasuite once the scan by another surgery room is finished. 

Video recording compression
The implemented compression mechanism allows recording full HD video not disturbing the smoothness of the performance while reducing storage used.

Fixes

The following issues have been resolved in the upgrade.

  1. MediaScan 2 interface crash when the scanner is unpowered
  2. Video duration absent for some videos in window Process Properties/Diagnoses
  3. Opening large image crashes Mediasuite
  4. CMScan support to Apixia PSP scanner
  5. CMS crash when exporting to not existing folder

Maintenance

  1. CMS update email and web site address in the About and Registration interfaces
  2. UI Refresh should update the DICOM statuses
  3. Sirona dental Unit interface to access all 3 buttons of the Foot Control
  4. DICOM Store add a flag to Redo DICOM store for selected objects

MediaSuite New Features Release - Build 4026

The following new and enhanced features are available in Build 4026 and higher.

New and Enhanced Features

Correction of Grayscale Images  
Grayscale images that have incorrect meta-data are automatically corrected using Auto Contract.

Mediascan: Setup and Capture interface enhancements 
  1. The PC name and Mediascan IP address is displayed in the Setup window 
  2. The plate count, plate serial number and Mediascan IP address is displayed in the Capture window 
Customised toolbar setting 
More options for saving customised toolbars have been added to Mediasuite.

EasyDent 3D objects can be exported after conversion
Ability to export 3D objects, in standard Dicom format, that have been imported after conversion from EasyDent.

Export objects via Windows Explorer  
Folder can be created in the Windows Explorer window when exporting an object from Mediasuite.

New Carestream 
The capture process has been streamlined by the new interface where bypasses the Carestream UI and multiple images can be taken.

Mediasuite Report
The date of when the image was taken is displayed in the report.

Import video files 
Ability to import Apple devices videos (.MOV format) into Mediasuite.

Default size for e-mail attachments 
The size of the e-mail attachment now defaults to
Original size.

Multicolour default preferences  
The default colour has changed from Sepia to Multicolour 1 to provide a more colourful palette.

Display deleted object 
The Display deleted objects no longer highlighted when a Study is deleted.

Fixes

The following issues have been resolved in the upgrade.

  1. Morita CBCT interface missing patient details.
  2. E-mail interface to use the system MAPI dLL.
  3. Unlimited imports after conversion from 3rd party system.
  4. Intermittent wrong icon orientation after refresh (F5).
  5. Export in DICOM format to support the tsclient path.
  6. Standalone: Fields Dentist and DOB to be saved when patient Card No is changed.

Maintenance

  1. MediaScan 2 interface to support new Fire CR Dental SDK and unit Firmware.
  2. Care Stream Dental interface to upgrade to the new SDK
  3. Acteon cameras button integration.

MediaSuite New Features Release - Build 4.018

Click on the below links to access information on how to set up and use new features available in the upgrade.
    • Related Articles

    • Dental4Web 2025 New Features

      WHATS NEW NOW The following new and enhanced features are available in: Build: 25.723 DB5808 Limited release starts from: 29/7/2025 General release: TBC New Features and / or Modules No new features are available in this build Enhancements & ...
    • Dental4Web 2023 New Features

      Release build: 23.1116 DB5429 on 24/11/23 MediaSuite Online Tab switching not working when invoked from Appt book selected patient Release build: 23.1109 DB5429 on 20/11/23 Landing Page Notifications Notifications will be posted by Centaur at various ...
    • Dental4Web 2024 New Features

      Release build: 24.1205 DB5685 on 11/12/24 Transfer from Treatment Plan The Transfer from Treatment Plan option is now available in the 2D or 3D Charting page when Show Treatment split screen option is on Referred To - Input Fields Input fields for ...
    • D4W Build Vi7 New Features

      WHATS NEW NOW The following new and enhanced features are available in: Build 5808 Limited release from: 13/03/2025 General release: TBC For instructions on how to upgrade, click here New Features and / or Modules National Dental Plan (NDP) powered ...
    • D4W Build Vi6 New features

      Previous Updates Vi6 Build 5429 / Release: 22/9/2023 New and Enhanced Features D4W and CoTreat Integration: Contact CoTreat for more information Expenses Categories Report: Person code field added when exporting report Fixes 2 x Optimisations and / ...