Setup & Manage Sterilisation Features in Dental4Windows

Setup & Manage Sterilisation Features in Dental4Windows

Listed below are instructions on adding or editing an autoclave and deleting or marking an autoclave as inactive. 

Setup Sterilisation Module

Notes
Once the Sterilisation module has been activated by Centaur, it is recommended the following preferences and setup is completed to ensure the onboarding of the module is effective. 
Dental4Windows can work with autoclaves that generate their own labels (e.g. Lisa), but are not recommend as they do not generate unique labels for each pack. Dental4Windows/PracticeStudio can generate labels that are just as cost effective.
The recommended label is Avery J8651 Inkjet or L7651EV, dimensions are: 38.1mm x 21.2mm, 65 labels per sheet.

Add an Autoclave to Sterilisation

All autoclaves must be added to the database. 
  1. Go to Location Management > Sterilisation tab
  2. Autoclave menu > New
    1. Location: Select the location, if applicable
    2. Name: Enter the name of the Autoclave
    3. Make: Enter the make details
    4. Model: Enter the model details
    5. Serial: Enter the serial details
    6. Notes: Add special notes about the autoclave

Add Sterilisation Pack Contents List

The contents of sterilised packs are entered into Dental4Windows via the System Tables.
This allows the user to identify the instruments that have been are scanned into an autoclave cycle.
Info
This suggestion list will help users setting up the Sterilisation Pack Contents. 

Set an Item Number to Record Sterilisation Packs on a Patient

When Sterilisation is activated, a new item number, STERI, is added to D4W. The item will automatically open the Clinical Notes window to the Sterilisation section, saving the user time in having hide other sections. Only one item can be marked as such, however other items can still record sterilisation entries. 

The below instructions are on how to mark and item as the Sterilisation item. 

  1. Go to Location Setup > Items tab
  2. Select the item
    1. Financial Details sub-tab
      1. Tick Sterilisation

Set Barcode Preferences

The following settings are related to sterilisation tracking barcode scanners. 

Generate and Print Sterilisation Labels

D4W can work with autoclaves that generate their own labels (e.g. Lisa), but are not recommend as they do not generate unique labels for each pack. D4W/PSS can generate labels that are just as cost effective.

The recommended label is Avery J8651 Inkjet or L7651EV, dimensions are: 38.1mm x 21.2mm, 65 labels per sheet.

  1. Go to Location Management > Sterilisation tab
  2. Autoclave menu > Generate & Print Labels
    1. Label Type: Select the relevant labels
    2. Bar Codes
      1. Initial: This will either be locked or open, depending on the setting (see link below for more information)
      2. Amount: Enter the number of labels to generate
    3. Address Position: Change the position of the barcode; only do this if test show it is needed
    4. Font: Change the size of the font if needed
    5. Print Setup: Ensure the correct printer is selected
    6. Click Print

Manage Autoclaves

Edit an Autoclave's Details

Existing autoclaves information can be update following the below steps. 
  1. Go to Location Management > Sterlisation tab
  2. Select the autoclave to be edited from the Autoclave list   
              
  3. Autoclave menu > Edit
    1. Make changes to the details
    2. Click OK     

Make an Autoclave Inactive

When an autoclave has been used, it cannot be deleted, therefore it should be made inactive to prevent users from entering details against it. 
  1. Go to Location Management > Sterilisation tab
  2. Select the autoclave to make inactive from the Autoclave list 
       
  3. Autoclave menu > Edit
    1. Remove tick from Active
    2. Click OK

Delete an Unused Autoclave

An autoclave can only be deleted if no records have been entered against it, otherwise it will need to be made inactive. 

  1. Go to Location Management > Sterilisation tab
  2. Select the autoclave to make inactive from the Autoclave list         

  3. Autoclave menu > Delete
    1. Click Yes to delete, or No to cancel
    • Related Articles

    • Setup & Manage Sterilisation Features in Dental4Web

      Use Sterilisation module to keep track of instruments sterilised content in packs and information on who, where, when they were used Where to find the Sterilisation Page Click the navigation menu > Management > Sterilisation page Setup Sterilisation ...
    • New Features

      What's New Now The following new and enhanced features are available in: Build 4.072 For instructions on how to upgrade, click here. MediaSuite New Features Release - Build 4.090 The following feature is available in Build 4.090 and higher. New ...
    • Dental4Web 2025 New Features

      WHATS NEW NOW Build: 25.903 DB5808 Limited release starts from: 05/09/2025 General release: 11/9/2025 Maintenance This build focuses on maintenance matters only COMING SOON Some of the New Features & Enhancements coming soon to D4Web NDP powered by ...
    • Dental4Web 2023 New Features

      Release build: 23.1116 DB5429 on 24/11/23 MediaSuite Online Tab switching not working when invoked from Appt book selected patient Release build: 23.1109 DB5429 on 20/11/23 Landing Page Notifications Notifications will be posted by Centaur at various ...
    • Manage Item Features in Dental4Windows

      Listed below are instructions on the ADA 13th item schedule, set missing tooth, eClaims attachment is required, mark an item as obsolete, search for an item, items list, ignore missing tooth, tooth ID or surface required, convert deciduous tooth to ...